Some of the technical content on this site is only available in English.

Controllers in Nebula Entry Beta

Overview

Controllers are mains-wired hardware devices that can be used to control access where a standalone lock cannot be fitted. This could be, for example, on car park barriers, turnstiles or sliding doors.

Controllers used in Salto Nebula

The BLUEnet Controller is a specific type of controller used in Salto Nebula which is designed to be used where a larger more complex installation is not required. This model currently only supports one reader device.

See also the BLUEnet Controller installation guide for more information.

Creating controllers

In a similar way to electronic locks, you use access points to manage the behavior of controllers within your installation's access plan. You connect a controller to an access point through its relay settings.

You can create controllers in Nebula via the web interface or using the Nebula Commissioning app during the device configuration process. If you create controllers via the web interface, they still need to be configured using the app.

Creating a controller in Salto Nebula EntryCreating a controller in Salto Nebula Entry

To configure a controller it needs to be connected to a reader device, like a Design XS Reader, for example.

For a full description of how to create and configure controllers see also the section on configuring controllers for installers.

Note that controllers are generally connected to readers. The reader is an electronic device often mounted on a wall or post beside an access point. Users present keys to the reader in order to gain access.

To create a controller, do the following:

  1. Go to Devices and select Create.
  2. Select Controller in the Type drop-down menu.
  3. Enter a Name for the controller.
  4. Select the Connection type: Online or Offline.
  5. If you select Online, select the gateway or extender that connects the controller in the Parent field.
  6. Under Relay settings, select the access point that the controller manages. See relay settings for more details.
  7. Select Create.

Example of an online configured controller in Salto Nebula EntryExample of an online configured controller in Salto Nebula Entry

Connection type

Controllers can be either online or offline.

Online

Online controllers, like the BLUEnet Controller, connect to Nebula through a parent device such as a gateway or an extender. If you're creating an online controller, select Online in the connection type.

You then need to select the parent device in the Parent field. When you start typing the name of the parent device, you see a list of the available gateways and extenders. The Parent field is required for online controllers.

Create the parent device in the Devices section before you create the controller that you want to associate with it.

In the Devices list, the Connection type column shows Online for controllers that have a parent device.

Offline

Offline controllers aren't connected to the Salto network. To make a change to an offline controller, update it using the Nebula Commissioning app. An offline controller doesn't have a parent device, so the Parent field is disabled when you select Offline.

Relay settings

The Relay settings section shows the relays of the controller's Master board. To connect the controller to an access point, do the following:

  1. Select the Relay 1 field. The Connect to relay 1 dialog opens.
  2. Select the access point that the controller manages. To leave the relay unassigned, select None.

If you connect Relay 1 to an access point, Relay 2 is disabled.

You must set at least one relay on the master board. Otherwise, the error "At least one relay must be set in this board." displays.

The Relay settings section of the device detail screen shows which access point each relay connects to. To open the device detail screen, select the controller in the Devices list.

Access point

As with electronic locks, you use access points to manage the behavior of controllers within your installation's access plan. If the controller's Name field is empty when you connect Relay 1 to an access point, the field fills with the name of that access point.

You manage settings such as opening modes and calendars on the access point, not on the controller. See creating access points for more information.

Salto Systems, S. L. uses third-party data storage and retrieval devices in order to allow secure browsing and gain a better understanding of how users interact with the website in order to improve our services. You can accept all cookies by clicking the "Accept cookies" button or reject their use by clicking the "Reject cookies" button. For more information, visit our Cookies Policy