Algunos de los contenidos técnicos de este sitio web solo están disponibles en inglés.

Click commands

Danalock V3 click commands

The Danalock V3 can be configured manually via the button found in the small pinhole on top of the lock.

The following tables lists all of the click commands for the Danalock V3.

The click commands are divided into two tables as the click commands for the Danalock V3 Homekit version are different from the other versions of the Danalock V3 (BT, BTZBE, and BTZE).

Click the button found in the small pinhole on top of the lock.Configure the lock manually by pressing the button found in the small pinhole.

Use the included pin tool or a paper clip to click the button. Avoid using a needle, as it may damage the button.

Click the button the specified number of times to change the desired setting. Once the correct number of clicks is reached, wait 5 seconds for the Danalock to respond.

If you click the wrong number of times, stop where the LED does not light up. Wait 5 seconds for the LED to flash red, indicating a timeout.

List of click commands

Danalock V3 BT, Zigbee, Z-Wave

ClicksColorVersiónActividad
1Z-Wave, ZigbeeInclusion/Exclusion Z-Wave: One click will include or exclude the lock from the Z-Wave network. Zigbee: The lock will join the Zigbee network.
2TodoManual calibration. Click the button 2 times. When flashing yellow, turn the lock to the fully unlocked position, as far as you can go. Then give the lock 1 click and now turn the lock to the fully locked position, as far as you can go. Give the lock 1 click and then turn the lock to the position where the lock is just unlocked, no further, and give the lock 1 click. Now turn the lock to the position where the lock is just locked, no further, and give the lock 1 click. If you have the Hold Back Latch feature enabled in the lock settings, now move the lock to the position where the latch is just about to retract, and give the lock 1 click.
3TodoSemi-automatic calibration. Turn the Danalock to the unlocked position and lift the handle if needed. If you have auto-lock enabled you might have to disable it first. Start the calibration by clicking 3 times - the lock will auto-calibrate and stop in the locked position. The light flashes - now turn the lock to the position where the lock is just unlocked, no further, and give the lock 1 click. Now turn the lock to the position where the lock is just locked, no further, and give the lock 1 click. If you have the Hold Back Latch feature enabled in the lock setting, then turn the lock to the position where the latch is just about to retract, and give the lock 1 click.
7 Z-Wave, ZigbeeAppless pairing Activates appless pairing mode to be used with Danapad V3 in cases where there is no app to provide the service.
9ZigbeeExclude Zigbee: The device will leave the Zigbee network. The Danalock flashes green during the process and confirms with a short green flash. If the process fails, it blinks red.
10TodoReset This action deletes all user settings on the Danalock. The Danalock responds by blinking red.

Danalock V3 Homekit

ClicksColorVersiónActividad
2HomekitManual calibration. Start by turning the Danalock to the desired unlocked position. Start the calibration with the click command and wait for the LED to start blinking yellow. Turn the Danalock to the desired locked position while the LED blinks and click the button once to save the locked position. The Danalock will confirm with a green blink.
3HomekitAuto calibration. Start by turning the Danalock to the unlocked position and lifting the handle if needed. The door has to be left open while the Danalock auto calibrates. Start the auto calibration with the click command. The Danalock will blink white while auto calibrating.
4HomekitHold-back-latch Toggles between 3 hold back latch settings: Off, short wait, and long wait. Every time this command is entered, the setting will switch to the next option. Off responds with a red blink when set and disables the hold-back latch. Short wait will respond with short green blinks when being set and will hold the latch back for 5 secs. Long wait will respond with one long green blink when being set and will hold the latch back for 15 secs
5HomekitAuto-lock Toggles between 3 auto-locking settings: Off, short wait, and long wait. Every time this command is entered, the setting will switch to the next option. Off will respond with a red blink when being set and will disable auto-locking. Short wait will respond with short green blinks when being set and will lock after 15 secs. Long wait will respond with one long green blink when being set and will lock after 60 secs.
6HomekitNext option. Turning on will respond with one green blink when being set Turning off will respond with one red blink when being set.
10HomekitReset. This action deletes all user settings on the Danalock. The Danalock responds by blinking red.

If you give the Danalock V3 HomeKit 10 clicks, all lock settings will be reset, and the lock will also be removed from Apple Home.

Salto Systems, S. L. utiliza dispositivos de almacenamiento y recuperación de datos de terceros para permitir una navegación más segura y comprender mejor cómo interactúan los usuarios con el sitio web con el fin de mejorar nuestros servicios. Puedes aceptar todas las cookies haciendo clic en el botón "Aceptar cookies" o rechazar su uso pulsando en el botón "Rechazar cookies". Para más información, visita nuestra Política de cookies