Mobile App - Commissioning

The XS4 Sense mobile app makes it easy to set up, configure, and manage your energy saving system. Installers can commission devices, connect them to the controller, and define how the system should work. Once configured, administrators and operators can use the app to monitor system status, check device health, and manage daily operations in real time. All from their smartphone.

XS4 Sense Dashboard and MonitorDashboard & Monitor

Download XS4 Sense mobile application

Download Apple App StoreiOS
Download Google PlayAndroid

Description

The XS4 Sense Mobile app is divided into three distinct sections:
Connection Setup, System Configuration and Monitoring and Administration.

Connection Setup

This section is used by installers and administrators to connect the XS4 Sense system to the local XS4 Sense Server and the XS4 Sense Cloud.

XS4 Sense Dashboard and SettingsAbout / Settings

XS4 Sense Server Setting

  • Click the gear icon to open the About / Settings section. In the Appliance server URL field, enter the IP address shown at the end of the server services installation process IP Address

It is important to enter the address in the following format, making sure to include the port 5555 at the end: i.e http://10.33.191.50:5555

  • If the XS4 Sense server is running, press CHECK CONNECTION to verify that the server is reachable. Make sure that the smartphone you are using is connected to a Wi-Fi network that can access the XS4 Sense server.

XS4 Sense Cloud Setting

  • Click the gear icon to open the About / Settings section. In the XS4 Sense Cloud URL field: https://xs4sense.saltosystems.com together with the received credentials.

Enter the credentials provided for commissioning activities. These can be generated from the Cloud Portal and are available in the Cloud Users section. The required access level for this user is Level 1. If you need to perform offline commissioning, you can skip the cloud authentication step.

  • By pressing CHECK CONNECTION, you can verify that the smartphone can reach the XS4 Sense cloud and authenticate successfully.

  • Press SAVE CONFIGURATION to complete the setup and save your changes.

Controller Settings

Through this section, you can modify the controller behaviors, define the sources, and set the basic parameters for the Wi-Fi connection.

XS4 Sense Controller SettingsController Settings

FunctionDescription
Assign a RoomDefines the room number, floor, and block. If the system is connected to SPACE BAS use the same Room Number on both sides.
Server URLAddress used by the controller to communicate with the XS4 Sense service.
IP/DHCPNetwork settings for enabling and configuring either a dynamic or static IP address.
Wi-FiConfiguration of the Wi-Fi network to be used by the controller.
Door Status SourceThe system allows defining the source of the door status information. The following options are available: - Digital Input 1 - Digital Input 2 - BLE Sensor - InRoomNode.
Window Status SourceThe system allows defining the source of the window status information. The following options are available: - Digital Input 1 - Digital Input 2 - BLE Sensor.
Energy Saving modeThe system allows enabling or disabling the function that saves energy when the room is not occupied by the guest.
Digital inputsThrough this setting, the system allows defining whether the digital inputs operate in Normal Open (NO) or Normal Closed (NC) mode. The default setting is Normal Open.
Multisensor 1Menu dedicated to the configuration of Multisensor 1, allowing you to define the behavior of - Sending IR commands - Setting a temperature correction offset - Adjusting the sensor sensitivity level.
Multisensor 2Menu dedicated to the configuration of Multisensor 2, allowing you to define the behavior of - Sending IR commands - Setting a temperature correction offset - Adjusting the sensor sensitivity level.

Controller Settings Expert mode

Click ENABLE EXPERT MODE. This section enables a set of advanced settings that allow changing sensitive parameters. Incorrect configuration may compromise the proper operation of the device. Change the values only if you are fully aware of the impact.

FunctionDescription
RelaysThe relay behavior is defined according to the changes in the room status, such as window open/closed, or transitions from Occupied to Tentatively Occupied and Unoccupied. For each of these conditions, the desired behavior can be configured.
Controller TX power levelDefines the transmission power level of the Wi-Fi connection in [dBm].
IR signal repeatsIndicates the number of IR command repetitions sent by the Multisensor.
BLE device absenceMaximum time after which, if the system no longer receives information from the BLE devices, the device is considered unreachable and an alarm is triggered in [minutes].
Multisensor Battery LowThe value in [millivolts] below which the battery is considered low.
Door sensor Battery LowThe value in [millivolts] below which the battery is considered low.
Preliminary occupation detectionDuration started from door close event to set room as tentatively unoccupied in [minutes].
Occupancy detectionDuration started from door close event to set room as unoccupied in [minutes].
False occupancy checkDuration from the last motion event to decide room is unoccupied in [hours].
Balcony/window delayDuration to trigger action from balcony/window open time in [seconds].

Controller Details

The mobile application includes a page called DETAILS to display all the behaviors of the controller and its sensors. Through this section, it is possible to check for any unexpected behaviors.

Bluetooth

FunctionDescription
MacThe controller MAC Address used for Bluetooth communication is displayed.
Signal levelSignal strength of the connection between the controller and the connected smartphone.

Network Information

FunctionDescription
MacThe controller MAC Address used for Wi-Fi communication is displayed.
ConnectedWi-Fi connection status. A green dot is shown when connected, and a grey dot when disconnected.
DHCPStatus of the DHCP functionality. A green dot indicates it is enabled, a grey dot indicates it is disabled.
Signal levelSignal strength of the connection between the controller and the connected access point.
IPIP address assigned to the controller, obtained from the DHCP service or set manually.
MaskRefers to the Subnet Mask.
GatewayAddress of the network device that allows the controller to communicate with devices outside the local network.

Appliance server availability

FunctionDescription
ConnectedConnection status between the XS4 Sense controller and the server. A green dot is shown when connected, and a grey dot when disconnected.
Server URLServer URL is the address used by the controller to connect to the XS4 Sense server. i.e http://ip_address:5555

inRoomNode

FunctionDescription
ConnectedConnection status between the XS4 Sense controller and the inRoomNode. A green dot is shown when connected, and a grey dot when disconnected.
Door StatusIndicates the door status: grey icon door closed, red icon door open.
Communication with lockIndicates the communication status between the electronic look and the inRoomNode module. A green dot is shown when connected, and a grey dot when disconnected.
PrivacyIndicates the activation of the deadbolt by the guest. A green dot indicates it is active, a grey dot indicates it is inactive.
Passage modeStatus about the function set by Salto Space
BatteryIndicates the battery status of the electronic lock. If the icon is red, it means the battery level is low.
Emergency modeStatus about the function set by Salto Space
Door left openIndicates an alarm situation where the door, after being properly opened, has been left open beyond the allowed time.
Intrusion alarmIndicates that the door has been opened without an authorized sequence, either from the inside or through an unauthorized opening.
Last card key operationIndicates the status of the last access, specifying whether it was made by a Guest or by Staff, and displays any unauthorized access attempt.

Operational details

FunctionDescription
Check-inIndicates the current status of the controller. A grey dot means check-out, a blue dot means check-in. The information is received either from a PMS system or from the webhook integration with Space.
Digital input 1Indicates the status of digital input 1. Grey dot input open, blue dot input closed.
Digital input 2Indicates the status of digital input 2. Grey dot input open, blue dot input closed.
Relay 1 StateIndicates the status of relay 1. Grey dot relay not activated, blue dot relay activated.
Relay 2 StateIndicates the status of relay 2. Grey dot relay not activated, blue dot relay activated.
Door statusIndicates the door status: blue dot door closed, grey dot door open.
Window/balcony statusIndicates the window status: blue dot window closed, grey dot window open.
Door status sourceIndicates which source has been assigned to the door function, choosing between digital input 1/2, BLE sensor, or inRoomNode.
Window status sourceIndicates which source has been assigned to the window function, choosing between digital input 1/2 or BLE sensor.
Energy savingIndicates which status has been assigned, choosing between Enable or Disable.
Room occupancyIndicates room occupancy status, obtained from the occupancy logic. Grey dot room not occupied, blue dot room occupied.
Room tentatively unoccupiedIndicates the state where the room is considered potentially unoccupied. It is triggered when the preliminary occupation detection time expires and remains active until the end of the occupancy detection period. Grey dot status active, blue dot status inactive.
MotionIndicates the motion detection status inside the room, based on the Multisensor. Grey dot no detection, blue dot detection.
Occupancy downcountIndicates the remaining time, in seconds, before the room status changes from occupied to unoccupied if no motion is detected.
Preliminary occupancy detectionIndicates the duration, in minutes, starting from the door close event until the room is set as tentatively unoccupied.
Occupancy detectionIndicates the duration started from door close event to set room as unoccupied in minutes [m].
False occupancy checkIndicate the duration from the last motion event to decide room is unoccupied in hours [h].
Balcony/window delayIndicate the duration to trigger action from balcony/window open time in seconds [s].
Controller TX Power levelIndicates the value of the configured Wi-Fi transmission power [dBm].
Input voltageIndicates the value of the supply voltage input to the controller [Volt].
CurrentIndicates the value of the instantaneous current measured by the controller [Ampere].
Instant powerIndicates the value of the instantaneous power measured by the controller [Watt].

Operational details sensors

Multisensor details

Each connected sensor communicates the following details, useful for diagnostics and maintenance.

FunctionDescription
Online statusIndicates the connection status of the sensor with the controller. Green dot indicates connected, grey dot indicates not connected, yellow triangle indicates the sensor is registered but not reachable by the controller.
MotionIndicates the status of the Multisensor in detecting presence in the room. Grey dot no presence, blue dot presence detected.
SensibilityIndicates the level of sensitivity of PIR device LOW, MED, HIGH. The default value is HIGH.
Battery levelIndicates the battery charge value in millivolts [mVolt]. The icon turns red when the charge level falls below the threshold set in the configuration.
Ambient temperatureIndicates the temperature value measured by the Multisensor, expressed in degrees Celsius [°C].
Ambient humidityIndicates the humidity [%] value measured by the Multisensor.
TX power levelIndicates the transmission power value set in the sensor.
Signal levelIndicates the BLE signal value received by the sensor.
MACIndicates the sensor MAC address.

Door/Window details

Each connected sensor communicates the following details, useful for diagnostics and maintenance.

FunctionDescription
Online statusIndicates the connection status of the sensor with the controller. Green dot indicates connected, grey dot indicates not connected, yellow triangle indicates the sensor is registered but not reachable by the controller.
Open/CloseIndicates the door or window opening status.
Battery levelIndicates the battery charge value in millivolts [mVolt]. The icon turns red when the charge level falls below the threshold set in the configuration.
TX power levelIndicates the transmission power value set in the sensor.
Signal levelIndicates the BLE signal value received by the sensor.
MACIndicates the sensor MAC address.

Monitoring and Administration

This section is described in this section

Salto Systems, S. L. uses third-party data storage and retrieval devices in order to allow secure browsing and gain a better understanding of how users interact with the website in order to improve our services. You can accept all cookies by clicking the "Accept cookies" button or reject their use by clicking the "Reject cookies" button. For more information, visit our Cookies Policy