Some of the technical content on this site is only available in English.

Mobile App - Monitoring

The mobile application is the main tool for monitoring the XS4 Sense system. It allows you to view the status of each installed controller and sensor and to assess any corrective actions needed to optimize system performance.

Download XS4 Sense mobile application

Download Apple App StoreiOS
Download Google PlayAndroid

Login

Use your credentials to log in. Depending on the authorization level associated with your account, you can view the system, manage it, and commission new controllers with their corresponding sensors.

XS4 Sense mobile loginMobile app login

Dashboard

Through the provided dashboard, it is possible to view an overview of the system's total energy consumption and savings. The filters allow you to define the data range to display, selecting a specific time period, a single room, or a group of rooms.

XS4 Sense mobile DashboardMobile app dashboard

Monitor

The Monitor screen of the XS4 Sense mobile application allows viewing the real-time status of all rooms configured in the system. Each card represents a room identified by its number and displays the main operational information, including:

  • Occupancy status (person icon)

  • Door status (open or closed door icon)

  • Window status (open or closed window/balcony icon)

  • WiFi signal strength (red icon means the controller is not reachable)

  • Battery level alert (red icon means low battery level)

  • Possible warnings or communication errors

  • Blue cards indicate rooms that are occupied, while grey cards represent unoccupied rooms.

XS4 Sense mobile MonitorMobile app monitor

Room detail

By clicking on a specific room, it is possible to view its detailed status and operational parameters. In the Main screen, the most relevant functions are displayed in a summarized way, while in the Room Details section, all information related to the XS4 Sense controller and its connected sensors is shown.

Main screen

In this section of the application, the overall health and operating status of each room are displayed in a clear and intuitive way.

XS4 Sense mobile Monitor single roomMobile app monitor single room

IconDescription
Person iconThe icon can have two states: blue when the room is occupied and grey when the room is unoccupied.
Wifi iconThe icon indicates the WiFi signal level with four states: high, medium, low, and no signal. When the no signal icon is displayed, it means the controller is offline.
Multisensor iconDisplays the motion status detected by the sensor and reports any low-battery alarms or registered but disconnected sensors.
Door iconDisplays the door status, open or closed and reports any low-battery alarms or registered but disconnected sensors.
Window iconDisplays the window/balcony status, (open or closed) and reports any low-battery alarms or registered but disconnected sensors.

Room details

In this section of the application, the detailed status of the selected room is displayed along with all connected sensors. This section is useful for accurately checking the status of each sensor and the proper operation of the system.

XS4 Sense mobile Monitor single roomMobile app monitor single room

Use caution when navigating within this menu, as you may unintentionally modify the real-time behavior of the XS4 Sense Controller, its sensors, or the default settings defined during the commissioning.

XS4 Sense Dashboard details sectionXS4 Sense Dashboard details section

IconDescription
Check-inIndicates the current status of the controller. A grey dot means check-out, a blue dot means check-in. The information is received either from a PMS system or from the webhook integration with Space.
Digital input 1Indicates the status of digital input 1. Grey dot input open, blue dot input closed.
Digital input 2Indicates the status of digital input 2. Grey dot input open, blue dot input closed.
Relay 1 StateIndicates the status of relay 1. Grey dot relay not activated, blue dot relay activated.
Only Local Users with the Engineering role can override the settings.
Relay 2 StateIndicates the status of relay 2. Grey dot relay not activated, blue dot relay activated.
Only Local Users with the Engineering role can override the settings.
Door status sourceIndicates which source has been assigned to the door function, choosing between digital input 1/2, BLE sensor, or inRoomNode.
Only Local Users with the Engineering role can modify the settings.
Window status sourceIndicates which source has been assigned to the window function, choosing between digital input 1/2 or BLE sensor.
Only Local Users with the Engineering role can modify the settings.
Energy saving modeIndicates which status has been assigned, choosing between Enable or Disable.
Only Local Users with the Engineering role can modify the settings.
Door statusIndicates the door status: blue dot door closed, grey dot door open.
Window/balcony statusIndicates the window status: blue dot window closed, grey dot window open.
Room occupancyIndicates room occupancy status, obtained from the occupancy logic. Grey dot room not occupied, blue dot room occupied.
Only Local Users with the Engineering role can override the settings.
Room tentatively unoccupiedIndicates the state where the room is considered potentially unoccupied. It is triggered when the preliminary occupation detection time expires and remains active until the end of the occupancy detection period. Grey dot status active, blue dot status inactive.
MotionIndicates the motion detection status inside the room, based on the Multisensor. Grey dot no detection, blue dot detection.
Preliminary occupancy detectionIndicates the duration, in minutes, starting from the door close event until the room is set as tentatively unoccupied.
Only Local Users with the Engineering role can modify the settings.
Occupancy detectionIndicates the duration started from door close event to set room as unoccupied in minutes [m].
Only Local Users with the Engineering role can modify the settings.
Balcony/window delayIndicate the duration to trigger action from balcony/window open time in seconds [s].
Only Local Users with the Engineering role can modify the settings.
False occupancy checkIndicate the duration from the last motion event to decide room is unoccupied in hours [h].
Only Local Users with the Engineering role can modify the settings.
BLE device absenceMaximum time after which, if the system no longer receives information from the BLE devices, the device is considered unreachable and an alarm is triggered in [minutes].
Only Local Users with the Engineering role can modify the settings.
Multisensor Battery LowThe value in [millivolts] below which the battery is considered low.
Only Local Users with the Engineering role can modify the settings.
Door sensor Battery LowThe value in [millivolts] below which the battery is considered low.
Only Local Users with the Engineering role can modify the settings.
Input voltageIndicates the value of the supply voltage input to the controller [Volt].
CurrentIndicates the value of the instantaneous current measured by the controller [Ampere].
Instant powerIndicates the value of the instantaneous power measured by the controller [Watt].

inRoomNode

XS4 Sense Dashboard inRoomNode DetailsXS4 Sense Dashboard inRoomNode informations

FunctionDescription
ConnectedConnection status between the XS4 Sense controller and the inRoomNode. A green dot is shown when connected, and a grey dot when disconnected.
Door StatusIndicates the door status: grey icon door closed, red icon door open.
Communication with lockIndicates the communication status between the electronic lock and the inRoomNode module. A green dot is shown when connected, and a grey dot when disconnected.
PrivacyIndicates the activation of the deadbolt by the guest. A green dot indicates it is active, a grey dot indicates it is inactive.
Passage modeStatus about the function set by Salto Space
BatteryIndicates the battery status of the electronic lock. If the icon is red, it means the battery level is low.
Emergency modeStatus about the function set by Salto Space
Door left openIndicates an alarm situation where the door, after being properly opened, has been left open beyond the allowed time.
Intrusion alarmIndicates that the door has been opened without an authorized sequence, either from the inside or through an unauthorized opening.
Last card key operationIndicates the status of the last access, specifying whether it was made by a Guest or by Staff, and displays any unauthorized access attempt.

Multisensor 1/2 details

XS4 Sense Dashboard Multisensor DetailsXS4 Sense Dashboard multisensors informations

Each connected sensor communicates the following details, useful for diagnostics and maintenance.

FunctionDescription
Online statusIndicates the connection status of the sensor with the controller. Green dot indicates connected, grey dot indicates not connected, yellow triangle indicates the sensor is registered but not reachable by the controller.
MotionIndicates the status of the Multisensor in detecting presence in the room. Grey dot no presence, blue dot presence detected.
SensibilityIndicates the level of sensitivity of PIR device LOW, MED, HIGH. The default value is HIGH.
Only Local Users with the Engineering role can modify the settings.
Battery levelIndicates the battery charge value in millivolts [mVolt]. The icon turns red when the charge level falls below the threshold set in the configuration.
Ambient temperatureIndicates the temperature value measured by the Multisensor, expressed in degrees Celsius [°C].
Temperature offsetSetting a temperature correction offset [°C].
Only Local Users with the Engineering role can modify the settings.
Ambient humidityIndicates the humidity [%] value measured by the Multisensor.
TX power levelIndicates the transmission power value set in the sensor.
Only Local Users with the Engineering role can modify the settings.
Signal levelIndicates the BLE signal value received by the sensor.

Door 1 / Window 1 to 3 details

XS4 Sense Dashboard Door/Window DetailsXS4 Sense Dashboard door/window informations

Each connected sensor communicates the following details, useful for diagnostics and maintenance.

FunctionDescription
Online statusIndicates the connection status of the sensor with the controller. Green dot indicates connected, grey dot indicates not connected, yellow triangle indicates the sensor is registered but not reachable by the controller.
Open/CloseIndicates the door or window opening status.
Battery levelIndicates the battery charge value in millivolts [mVolt]. The icon turns red when the charge level falls below the threshold set in the configuration.
TX power levelIndicates the transmission power value set in the sensor.
Only Local Users with the Engineering role can modify the settings.
Signal levelIndicates the BLE signal value received by the sensor.

Use caution when navigating within this menu, as you may unintentionally modify the real-time behavior of the XS4 Sense Controller, its sensors, or the default settings defined during the commissioning.

Salto Systems, S. L. uses third-party data storage and retrieval devices in order to allow secure browsing and gain a better understanding of how users interact with the website in order to improve our services. You can accept all cookies by clicking the "Accept cookies" button or reject their use by clicking the "Reject cookies" button. For more information, visit our Cookies Policy