# How to configure destinations in Salto Nebula Entry
> Set up and manage destinations in the Salto Nebula Entry access control platform, including elevator floors and controlled access points.


## Overview {#overview}

Destinations represent secured points of entry or exit within an installation that can only be accessed by users with appropriate permissions.
The primary use case is elevator control (where presenting a key to a reader activates only the buttons for floors the user has access to), however destinations could also represent any access-controlled output that requires selective activation based on user credentials.

### How destinations work in Salto Nebula Entry {#how-destinations-work-in-salto-nebula-entry}

- **Functionality:** In an elevator scenario, users present a key at a {{< glossary_term "reader" >}}reader{{< /glossary_term >}}, which is attached to a {{< glossary_term "controller" >}}controller{{< /glossary_term >}}.
The system then, based on their permissions (which can be time-dependent, [based on schedules](/nebula-entry/user-guide/system-manager/access-rights/schedules)), enables access to specific destinations by enabling or illuminating corresponding buttons on the elevator panel.
- **Entities affected:**
  - **Destinations:** The actual locations (first floor, second floor, garage, attic).
  Destinations could also be 2 exit or entry points on the same floor (for example, second floor, exit A and second floor, exit B).
  - **Access rights:** Permissions granted to users.
  These include destinations in addition to access points.
  - **Access right destination:** The link between an access right and a specific destination.

{{% info-panel %}}
Destinations work with the [BLUEnet Controller](/installation-guides/controllers/bluenet) range of devices.
{{% /info-panel %}}

### Technical implementation details {#technical-implementation-details}

- **Controllers:** These devices are central to how destinations work.
A controller with relays is used.
Each relay can correspond to an elevator button, which in turn is a destination.
- **Hardware configuration:**
  - A controller has a **master board** (for example, the BLUEnet Controller standard unit has 2 relays and 2 programmable inputs on its master board).
  - {{< glossary_term "output_expansion_unit" >}}Output expansion units{{< /glossary_term >}} (standard expansion boards) can be added (up to 16), each providing additional relays (typically 4 per expansion unit).
  This allows for a large number of destinations (typically up to 66 or 68, depending on the master board).
  - {{< glossary_term "exit_reader_unit" >}}Exit reader units{{< /glossary_term >}} can be added as needed for additional reader points, enabling separate entry and exit control with a second wall reader.
  Although an exit reader unit has its own relays, it doesn't provide an additional access point or destination.
  - **Installation distance:** the controller's master board and each output expansion unit or exit reader unit must be installed within 1 meter of each other, since they communicate over a serial bus.
  - **DIP switches:** Installers need to physically configure DIP switches on the expansion boards sequentially (0000, 0001, 0010, 0011, and so on) as they are added, with switches numbered 1 to 4 for easy identification.

Output expansion units and exit reader units are accessories added to an existing controller, not device types you create separately in **Settings** > **Devices**.

#### Relay assignment logic {#relay-assignment-logic}

{{% info-panel %}}
A controller can manage **either** one **access point** **or** multiple **destinations**, but **not both simultaneously**.
{{% /info-panel %}}

- If you choose an access point, Nebula Entry web disables the other relay assignments and expansion controls.
- If you choose a destination, multiple destinations can be linked to the available relays.

See the [relay settings section in the controllers guide](/nebula-entry/user-guide/system-manager/settings/devices/controllers#relay-settings) for how to make this choice per relay.

{{% info-panel %}}
If you change the purpose of a controller from enabling destinations to access points or vice versa, you must [reset](/nebula/user-guide/installer/maintain-devices/reset) and [reconfigure](/nebula/user-guide/installer/configure-devices/controllers) the controller.
<!-- TODO: This may change in the future. -->
{{% /info-panel %}}

- **Managing access points and destinations:**
  - Access points can either be created together with [their associated electronic locks](/nebula-entry/user-guide/system-manager/settings/devices/electronic-locks) or separately in the **Access points** section if they are to be associated with controllers.
  - In **Settings**, you can create and manage destinations as separate entities before [including them in access rights](/nebula-entry/user-guide/system-manager/access-rights/create-access-right).
  This differs from creating access points together with electronic locks.

{{% info-panel %}}
The [passcodes feature of Nebula Entry](/nebula-entry/user-guide/system-manager/users/assign-keys#passcodes) is not currently supported with destinations.
Users cannot use readers fitted with keypads to access destinations at the moment.
<!-- TODO: This will be supported in the future. -->
{{% /info-panel %}}

### BLUEnet Controller settings {#bluenet-controller-settings}

![BLUEnet Controller settings](images/bluenet-controller-settings.png "To use the destinations feature, you need to configure a BLUEnet Controller device")
{.border}

#### Legend {#legend}

1. Input/Output: power input/output and proprietary serial bus for communication with
expansion boards. There are two groups of connections that are identical.
2. Relay outputs: (1A/30VDC).
3. Connection with the reader: consult the [reader installation guides](/installation-guides/readers) for more detailed information about the type of recommended wiring, connections and
maximum distances.
4. Inputs: inputs for external configuration (default, IN2, tamper).
5. **Clear** button: short press (< 3 seconds) to pair with the connected wall reader and discover and pair devices on the proprietary serial bus.

## Creating destinations {#creating-destinations}

To create a destination go to **Settings** > **Destinations** and select **Create**.

You only need to enter a name for the destination.
For example, **First floor**, **Second floor**, **Garage**, etc.

![Destinations example](images/destinations.png "An example of destinations created in the 'Settings' section")
{.border}

## Associating destinations to controllers {#associating-destinations-to-controllers}

Once you have created a destination, you can associate it with a controller's relays during the controller setup process.
To do this, you need to create a controller first.

![Associating destinations with a controller](images/controller-add-destinations.png "Associating destinations with a controller")
{.border}

For more information on how to create controllers and associate the controller's relays to destinations, see the [section on creating controllers](/nebula-entry/user-guide/system-manager/settings/devices/controllers).

## Creating access points {#creating-access-points}

If you **only** want to associate an access point, rather than destinations, with the controller, first create the access point in the **Access points** section.
After that, you can associate the access point with the controller's relay in a similar way as you would with destinations.

The BLUEnet Controller device currently allows you to associate one access point per controller.

See the section on [creating access points](/nebula-entry/user-guide/system-manager/access-points/create-access-points) for more information.